+//The following data is taken from http://www.proxmark.org/forum/viewtopic.php?pid=13501#p13501
+/*
+ISO14443A (usually NFC tags)
+ 26 (7bits) = REQA
+ 30 = Read (usage: 30+1byte block number+2bytes ISO14443A-CRC - answer: 16bytes)
+ A2 = Write (usage: A2+1byte block number+4bytes data+2bytes ISO14443A-CRC - answer: 0A [ACK] or 00 [NAK])
+ 52 (7bits) = WUPA (usage: 52(7bits) - answer: 2bytes ATQA)
+ 93 20 = Anticollision (usage: 9320 - answer: 4bytes UID+1byte UID-bytes-xor)
+ 93 70 = Select (usage: 9370+5bytes 9320 answer - answer: 1byte SAK)
+ 95 20 = Anticollision of cascade level2
+ 95 70 = Select of cascade level2
+ 50 00 = Halt (usage: 5000+2bytes ISO14443A-CRC - no answer from card)
+Mifare
+ 60 = Authenticate with KeyA
+ 61 = Authenticate with KeyB
+ 40 (7bits) = Used to put Chinese Changeable UID cards in special mode (must be followed by 43 (8bits) - answer: 0A)
+ C0 = Decrement
+ C1 = Increment
+ C2 = Restore
+ B0 = Transfer
+Ultralight C
+ A0 = Compatibility Write (to accomodate MIFARE commands)
+ 1A = Step1 Authenticate
+ AF = Step2 Authenticate
+
+
+ISO14443B
+ 05 = REQB
+ 1D = ATTRIB
+ 50 = HALT
+SRIX4K (tag does not respond to 05)
+ 06 00 = INITIATE
+ 0E xx = SELECT ID (xx = Chip-ID)
+ 0B = Get UID
+ 08 yy = Read Block (yy = block number)
+ 09 yy dd dd dd dd = Write Block (yy = block number; dd dd dd dd = data to be written)
+ 0C = Reset to Inventory
+ 0F = Completion
+ 0A 11 22 33 44 55 66 = Authenticate (11 22 33 44 55 66 = data to authenticate)
+
+
+ISO15693
+ MANDATORY COMMANDS (all ISO15693 tags must support those)
+ 01 = Inventory (usage: 260100+2bytes ISO15693-CRC - answer: 12bytes)
+ 02 = Stay Quiet
+ OPTIONAL COMMANDS (not all tags support them)
+ 20 = Read Block (usage: 0220+1byte block number+2bytes ISO15693-CRC - answer: 4bytes)
+ 21 = Write Block (usage: 0221+1byte block number+4bytes data+2bytes ISO15693-CRC - answer: 4bytes)
+ 22 = Lock Block
+ 23 = Read Multiple Blocks (usage: 0223+1byte 1st block to read+1byte last block to read+2bytes ISO15693-CRC)
+ 25 = Select
+ 26 = Reset to Ready
+ 27 = Write AFI
+ 28 = Lock AFI
+ 29 = Write DSFID
+ 2A = Lock DSFID
+ 2B = Get_System_Info (usage: 022B+2bytes ISO15693-CRC - answer: 14 or more bytes)
+ 2C = Read Multiple Block Security Status (usage: 022C+1byte 1st block security to read+1byte last block security to read+2bytes ISO15693-CRC)
+
+EM Microelectronic CUSTOM COMMANDS
+ A5 = Active EAS (followed by 1byte IC Manufacturer code+1byte EAS type)
+ A7 = Write EAS ID (followed by 1byte IC Manufacturer code+2bytes EAS value)
+ B8 = Get Protection Status for a specific block (followed by 1byte IC Manufacturer code+1byte block number+1byte of how many blocks after the previous is needed the info)
+ E4 = Login (followed by 1byte IC Manufacturer code+4bytes password)
+NXP/Philips CUSTOM COMMANDS
+ A0 = Inventory Read
+ A1 = Fast Inventory Read
+ A2 = Set EAS
+ A3 = Reset EAS
+ A4 = Lock EAS
+ A5 = EAS Alarm
+ A6 = Password Protect EAS
+ A7 = Write EAS ID
+ A8 = Read EPC
+ B0 = Inventory Page Read
+ B1 = Fast Inventory Page Read
+ B2 = Get Random Number
+ B3 = Set Password
+ B4 = Write Password
+ B5 = Lock Password
+ B6 = Bit Password Protection
+ B7 = Lock Page Protection Condition
+ B8 = Get Multiple Block Protection Status
+ B9 = Destroy SLI
+ BA = Enable Privacy
+ BB = 64bit Password Protection
+ 40 = Long Range CMD (Standard ISO/TR7003:1990)
+ */
+