1#ifndef PROTOCOLS_H
2#define PROTOCOLS_H
3
4//The following data is taken from http://www.proxmark.org/forum/viewtopic.php?pid=13501#p13501
5/*
6ISO14443A (usually NFC tags)
7 26 (7bits) = REQA
8 30 = Read (usage: 30+1byte block number+2bytes ISO14443A-CRC - answer: 16bytes)
9 A2 = Write (usage: A2+1byte block number+4bytes data+2bytes ISO14443A-CRC - answer: 0A [ACK] or 00 [NAK])
10 52 (7bits) = WUPA (usage: 52(7bits) - answer: 2bytes ATQA)
11 93 20 = Anticollision (usage: 9320 - answer: 4bytes UID+1byte UID-bytes-xor)
12 93 70 = Select (usage: 9370+5bytes 9320 answer - answer: 1byte SAK)
13 95 20 = Anticollision of cascade level2
14 95 70 = Select of cascade level2
15 50 00 = Halt (usage: 5000+2bytes ISO14443A-CRC - no answer from card)
16Mifare
17 60 = Authenticate with KeyA
18 61 = Authenticate with KeyB
19 40 (7bits) = Used to put Chinese Changeable UID cards in special mode (must be followed by 43 (8bits) - answer: 0A)
20 C0 = Decrement
21 C1 = Increment
22 C2 = Restore
23 B0 = Transfer
24Ultralight C
25 A0 = Compatibility Write (to accomodate MIFARE commands)
26 1A = Step1 Authenticate
27 AF = Step2 Authenticate
28
29
30ISO14443B
31 05 = REQB
32 1D = ATTRIB
33 50 = HALT
c5f8c67a 34
35 BA = PING (reader -> tag)
36 AB = PONG (tag -> reader)
b67f7ec3
MHS
37SRIX4K (tag does not respond to 05)
38 06 00 = INITIATE
39 0E xx = SELECT ID (xx = Chip-ID)
40 0B = Get UID
41 08 yy = Read Block (yy = block number)
42 09 yy dd dd dd dd = Write Block (yy = block number; dd dd dd dd = data to be written)
43 0C = Reset to Inventory
44 0F = Completion
45 0A 11 22 33 44 55 66 = Authenticate (11 22 33 44 55 66 = data to authenticate)
46
47
48ISO15693
49 MANDATORY COMMANDS (all ISO15693 tags must support those)
50 01 = Inventory (usage: 260100+2bytes ISO15693-CRC - answer: 12bytes)
51 02 = Stay Quiet
52 OPTIONAL COMMANDS (not all tags support them)
53 20 = Read Block (usage: 0220+1byte block number+2bytes ISO15693-CRC - answer: 4bytes)
54 21 = Write Block (usage: 0221+1byte block number+4bytes data+2bytes ISO15693-CRC - answer: 4bytes)
55 22 = Lock Block
56 23 = Read Multiple Blocks (usage: 0223+1byte 1st block to read+1byte last block to read+2bytes ISO15693-CRC)
57 25 = Select
58 26 = Reset to Ready
59 27 = Write AFI
60 28 = Lock AFI
61 29 = Write DSFID
62 2A = Lock DSFID
63 2B = Get_System_Info (usage: 022B+2bytes ISO15693-CRC - answer: 14 or more bytes)
64 2C = Read Multiple Block Security Status (usage: 022C+1byte 1st block security to read+1byte last block security to read+2bytes ISO15693-CRC)
65
66EM Microelectronic CUSTOM COMMANDS
67 A5 = Active EAS (followed by 1byte IC Manufacturer code+1byte EAS type)
68 A7 = Write EAS ID (followed by 1byte IC Manufacturer code+2bytes EAS value)
69 B8 = Get Protection Status for a specific block (followed by 1byte IC Manufacturer code+1byte block number+1byte of how many blocks after the previous is needed the info)
70 E4 = Login (followed by 1byte IC Manufacturer code+4bytes password)
71NXP/Philips CUSTOM COMMANDS
72 A0 = Inventory Read
73 A1 = Fast Inventory Read
74 A2 = Set EAS
75 A3 = Reset EAS
76 A4 = Lock EAS
77 A5 = EAS Alarm
78 A6 = Password Protect EAS
79 A7 = Write EAS ID
80 A8 = Read EPC
81 B0 = Inventory Page Read
82 B1 = Fast Inventory Page Read
83 B2 = Get Random Number
84 B3 = Set Password
85 B4 = Write Password
86 B5 = Lock Password
87 B6 = Bit Password Protection
88 B7 = Lock Page Protection Condition
89 B8 = Get Multiple Block Protection Status
90 B9 = Destroy SLI
91 BA = Enable Privacy
92 BB = 64bit Password Protection
93 40 = Long Range CMD (Standard ISO/TR7003:1990)
c5f8c67a 94
95ISO 7816-4 Basic interindustry commands. For command APDU's.
96 B0 = READ BINARY
97 D0 = WRITE BINARY
98 D6 = UPDATE BINARY
99 0E = ERASE BINARY
100 B2 = READ RECORDS
101 D2 = WRITE RECORDS
102 E2 = APPEND RECORD
103 DC = UPDATE RECORD
104 CA = GET DATA
105 DA = PUT DATA
106 A4 = SELECT FILE
107 20 = VERIFY
108 88 = INTERNAL AUTHENTICATION
109 82 = EXTERNAL AUTHENTICATION
110 B4 = GET CHALLENGE
111 70 = MANAGE CHANNEL
112
113 For response APDU's
114 90 00 = OK
115 6x xx = ERROR
116*/
b67f7ec3
MHS
117
118#define ICLASS_CMD_ACTALL 0x0A
119#define ICLASS_CMD_READ_OR_IDENTIFY 0x0C
120#define ICLASS_CMD_SELECT 0x81
121#define ICLASS_CMD_PAGESEL 0x84
122#define ICLASS_CMD_READCHECK_KD 0x88
123#define ICLASS_CMD_READCHECK_KC 0x18
124#define ICLASS_CMD_CHECK 0x05
125#define ICLASS_CMD_DETECT 0x0F
126#define ICLASS_CMD_HALT 0x00
127#define ICLASS_CMD_UPDATE 0x87
128#define ICLASS_CMD_ACT 0x8E
129#define ICLASS_CMD_READ4 0x06
130
131
132#define ISO14443A_CMD_REQA 0x26
133#define ISO14443A_CMD_READBLOCK 0x30
134#define ISO14443A_CMD_WUPA 0x52
135#define ISO14443A_CMD_ANTICOLL_OR_SELECT 0x93
136#define ISO14443A_CMD_ANTICOLL_OR_SELECT_2 0x95
2c39c25c 137#define ISO14443A_CMD_WRITEBLOCK 0xA0
b67f7ec3
MHS
138#define ISO14443A_CMD_HALT 0x50
139#define ISO14443A_CMD_RATS 0xE0
140
141#define MIFARE_AUTH_KEYA 0x60
142#define MIFARE_AUTH_KEYB 0x61
16a95d76 143#define MIFARE_MAGICWUPC1 0x40
144#define MIFARE_MAGICWUPC2 0x43
145#define MIFARE_MAGICWIPEC 0x41
b67f7ec3
MHS
146#define MIFARE_CMD_INC 0xC0
147#define MIFARE_CMD_DEC 0xC1
148#define MIFARE_CMD_RESTORE 0xC2
149#define MIFARE_CMD_TRANSFER 0xB0
150
a98b05b7 151#define MIFARE_ULC_WRITE 0xA2
152//#define MIFARE_ULC__COMP_WRITE 0xA0
b67f7ec3 153#define MIFARE_ULC_AUTH_1 0x1A
11b1e2e5 154#define MIFARE_ULC_AUTH_2 0xAF
7d010c49 155
11b1e2e5 156#define MIFARE_ULEV1_AUTH 0x1B
7d010c49 157#define MIFARE_ULEV1_VERSION 0x60
11b1e2e5 158#define MIFARE_ULEV1_FASTREAD 0x3A
11b1e2e5 159#define MIFARE_ULEV1_READ_CNT 0x39
160#define MIFARE_ULEV1_INCR_CNT 0xA5
161#define MIFARE_ULEV1_READSIG 0x3C
162#define MIFARE_ULEV1_CHECKTEAR 0x3E
163#define MIFARE_ULEV1_VCSL 0x4B
b67f7ec3
MHS
164
165/**
16606 00 = INITIATE
1670E xx = SELECT ID (xx = Chip-ID)
1680B = Get UID
16908 yy = Read Block (yy = block number)
17009 yy dd dd dd dd = Write Block (yy = block number; dd dd dd dd = data to be written)
1710C = Reset to Inventory
1720F = Completion
1730A 11 22 33 44 55 66 = Authenticate (11 22 33 44 55 66 = data to authenticate)
174**/
175
176#define ISO14443B_REQB 0x05
177#define ISO14443B_ATTRIB 0x1D
178#define ISO14443B_HALT 0x50
179#define ISO14443B_INITIATE 0x06
180#define ISO14443B_SELECT 0x0E
181#define ISO14443B_GET_UID 0x0B
182#define ISO14443B_READ_BLK 0x08
183#define ISO14443B_WRITE_BLK 0x09
184#define ISO14443B_RESET 0x0C
185#define ISO14443B_COMPLETION 0x0F
186#define ISO14443B_AUTHENTICATE 0x0A
c5f8c67a 187#define ISO14443B_PING 0xBA
188#define ISO14443B_PONG 0xAB
b67f7ec3
MHS
189
190//First byte is 26
191#define ISO15693_INVENTORY 0x01
192#define ISO15693_STAYQUIET 0x02
193//First byte is 02
194#define ISO15693_READBLOCK 0x20
195#define ISO15693_WRITEBLOCK 0x21
196#define ISO15693_LOCKBLOCK 0x22
197#define ISO15693_READ_MULTI_BLOCK 0x23
198#define ISO15693_SELECT 0x25
199#define ISO15693_RESET_TO_READY 0x26
200#define ISO15693_WRITE_AFI 0x27
201#define ISO15693_LOCK_AFI 0x28
202#define ISO15693_WRITE_DSFID 0x29
203#define ISO15693_LOCK_DSFID 0x2A
204#define ISO15693_GET_SYSTEM_INFO 0x2B
205#define ISO15693_READ_MULTI_SECSTATUS 0x2C
206
207
0ec548dc 208// Topaz command set:
209#define TOPAZ_REQA 0x26 // Request
210#define TOPAZ_WUPA 0x52 // WakeUp
211#define TOPAZ_RID 0x78 // Read ID
212#define TOPAZ_RALL 0x00 // Read All (all bytes)
213#define TOPAZ_READ 0x01 // Read (a single byte)
214#define TOPAZ_WRITE_E 0x53 // Write-with-erase (a single byte)
215#define TOPAZ_WRITE_NE 0x1a // Write-no-erase (a single byte)
216// additional commands for Dynamic Memory Model
217#define TOPAZ_RSEG 0x10 // Read segment
218#define TOPAZ_READ8 0x02 // Read (eight bytes)
219#define TOPAZ_WRITE_E8 0x54 // Write-with-erase (eight bytes)
220#define TOPAZ_WRITE_NE8 0x1B // Write-no-erase (eight bytes)
221
222
c5f8c67a 223#define ISO_14443A 0
224#define ICLASS 1
225#define ISO_14443B 2
0ec548dc 226#define TOPAZ 3
c5f8c67a 227#define ISO_7816_4 4
b67f7ec3 228
1defcf60
MHS
229//-- Picopass fuses
230#define FUSE_FPERS 0x80
231#define FUSE_CODING1 0x40
232#define FUSE_CODING0 0x20
233#define FUSE_CRYPT1 0x10
234#define FUSE_CRYPT0 0x08
235#define FUSE_FPROD1 0x04
236#define FUSE_FPROD0 0x02
237#define FUSE_RA 0x01
238
c5f8c67a 239// ISO 7816-4 Basic interindustry commands. For command APDU's.
240#define ISO7816_READ_BINARY 0xB0
241#define ISO7816_WRITE_BINARY 0xD0
242#define ISO7816_UPDATE_BINARY 0xD6
243#define ISO7816_ERASE_BINARY 0x0E
244#define ISO7816_READ_RECORDS 0xB2
245#define ISO7816_WRITE_RECORDS 0xD2
246#define ISO7816_APPEND_RECORD 0xE2
247#define ISO7816_UPDATE_RECORD 0xDC
248#define ISO7816_GET_DATA 0xCA
249#define ISO7816_PUT_DATA 0xDA
250#define ISO7816_SELECT_FILE 0xA4
251#define ISO7816_VERIFY 0x20
252#define ISO7816_INTERNAL_AUTHENTICATION 0x88
253#define ISO7816_EXTERNAL_AUTHENTICATION 0x82
254#define ISO7816_GET_CHALLENGE 0xB4
255#define ISO7816_MANAGE_CHANNEL 0x70
1defcf60 256
c5f8c67a 257// ISO7816-4 For response APDU's
258#define ISO7816_OK 0x9000
259// 6x xx = ERROR
260
1defcf60 261void printIclassDumpInfo(uint8_t* iclass_dump);
b67f7ec3
MHS
262
263#endif // PROTOCOLS_H